Design it. Then break it.

Put an Oracle architecture together from real building blocks, then pull a plug. The map shows what happens. The clock shows what your applications would notice.

Rings on the map are OCI regions. Click one to place the cloud standby there.

Break something

The same failure, other designs

How much protection you need is a business decision. Not every database needs every layer.

    What each layer is for.

    Four building blocks, four different failures. We size the combination to your systems, your budget and the hardware you already own.

    RAC

    Two or more servers, one database. Covers a server failure and lets you patch one server at a time. It does not cover the loss of a site.

    Data Guard

    A second database kept in step by shipping redo. Synchronous transport loses nothing, asynchronous transport never makes commits wait.

    Fast-Start Failover

    An observer at a third location makes the decision in seconds. Without it the outage lasts as long as it takes a person to react.

    Flashback

    The only layer that helps when the data itself is wrong. Everything else faithfully replicates the mistake.

    What the simulation assumes.

    Oracle defaults where a default exists, typical values where it does not. Your numbers will differ, and that is the point of a design.

    • Fast-Start Failover threshold: 30 seconds (Oracle default).
    • Role change of the standby: about 12 seconds. Applications reconnect in about 6 seconds.
    • RAC reconfiguration after a server loss: about 8 seconds.
    • Synchronous redo destination timeout: 30 seconds (Oracle default).
    • Asynchronous transport lag at the moment of failure: about 3 seconds.
    • Manual failover: 25 minutes from alert to command.
    • Replacing a dead server without a cluster or standby: 4 hours.
    • Rebuilding a lost site from off-site backup: 2 days, with a backup that is up to 24 hours old.
    • Flashback: 10 minutes. Recovery from a backup copy: 4 hours.
    • Network round trip: 1.5 times the straight-line distance at 200 km per millisecond, plus 0.4 ms.

    Which of these layers do your systems need?

    In a free consultation we go through your current architecture and the outages it would not survive.